Posts Tagged add

Operation failed, diagnostics report: iScsi Adapter in unbound status, adding Static Target can not be done.


Hello,

You might see error in VMWare ESXi when LUN is created in EMC VNX3150 and you grant access to hosts that added to the VNXe3150.

Operation failed, diagnostics report: iScsi Adapter in unbound status, adding Static Target can not be done.

VNXe3150 Error in ESXi
This error is generated because EMC VNXe3150 try’s to add the iSCSI Servers/Targets that configured in the EMC VNX to each ESX that granted access to the LUNs. While the iSCSI Targets already added in the Dynamic/Static iSCSI Targets tab, this error is generated.

I think EMC should introduce some logic into the EMC VNXe3150 SAN Storage to initially check the Host if the iSCSI Targets already added, adding iSCSI targets via EMC should be ignored.

Or, VNXe3150 should loop through the storage pools/LUNs where it finds LUNs already presented to ESX hosts from the same Array, adding iSCSI Targets through EMC VNXe3150 should be ignored. Otherwise this fake error will keep presenting itself.

, , , ,

Leave a comment

Cannot add Windows PowerShell snap-in VeeamPSSnapin


You may encounter an error Cannot add Windows PowerShell snap-in VeeamPSSnapin when you run PowerShell scripts on Veeam Backup & Replication to start Backup Jobs after an upgrade from Veeam  Backup v6.x to v6.5

Symptoms:

  • PowerShell Scripts scheduled via Task Scheduler doesn’t start automatically.
  • If you run the script manually via Veeam PowerShell snap-in VeeamPSSnapin, you will receive an error. Cannot add Windows PowerShell snap-in VeeamPSSnapin. But the job will start.

Solution:

Upgrade to PowerShell 3.0 by installing Windows Management Framework 3.0 (http://www.microsoft.com/en-us/download … x?id=34595) which supports .Net 4.0 natively.

, , , , , , , ,

Leave a comment